Skip to content
Search
lg@lugsicher.com+86 21 5666 0068 Mobile +86 199 4601 0778
Menu

Data and line integration

Readable Code, False Reject: Five Checks on the Line

Reconstruct the exact inspection cycle to separate image quality, timing, item tracking, business validation and physical rejection.

1. Review the original frame

Inspect the image captured at the decision, including glare, blur, field position and contrast. A later stationary reread uses different conditions.

2. Check when the result arrived

Compare trigger, image, decision and PLC timestamps with the available response window.

3. Verify product association

Follow the image and result to the item that reached the reject point. Test missing units, changing pitch and the result queue after restart.

4. Read the reason for rejection

Separate decoding failure from wrong content, a duplicate, an incorrect template or a failed business rule.

5. Confirm the physical action

Compare the commanded reject, feedback and actual rejected sample. Record the event identifiers and timing before changing thresholds.

Discuss your application

Share your material, mark file and line conditions so we can review sample testing and integration.

Send an application enquiry